125 dia. x 300 long twin wall flue pipe
|
 |
125 dia. x 500 long twin wall flue pipe
|
 |
125 dia. x 1000 long twin wall flue pipe
|
 |
125 dia. x 1500 long twin wall flue pipe
|
 |
125 dia. x 320 - 520 long adjustable twin wall flue pipe
|
 |
125 dia. x 520 - 920 long adjustable twin wall flue pipe
|
 |
125 x 15 deg. elbow Used to provide a 15 deg. change of direction. Two fittings provide a 34 mm offset with a length of 260 mm.
|
 |
125 x 30 deg. elbow Used to provide a 30 deg. change of direction. Two fittings provide a 79 mm offset with a length of 295 mm.
|
 |
125 x 45 deg. elbow Used to provide a 45 deg. change of direction. Two fittings provide a 130 mm offset with a length of 314 mm.
|
 |
125 dia. x 45 deg tee Requires a 'tee cap' to blank-off cleaning opening.
|
 |
125 dia. x 90 deg tee Requires a 'tee cap' to blank-off cleaning opening.
|
 |
125 dia. tee cap Used to close off unused opening on tee fittings. Allows easy access for cleaning.
|
 |
125 dia. tee cap with drain point Used to close off unused opening on tee fittings. Allows easy access for cleaning and draining.
|
 |
125 dia. flat roof plate 456 x 456 aluminium plate with upstand.
|
 |
125 dia. adjustable roof plate 610 x 610 aluminium plate for 0-30 deg. roof pitch. For use with slate roof.
|
 |
125 dia. adjustable roof plate 610 x 610 aluminium plate for 25-45 deg. roof pitch. For use with slate roof.
|
 |
125 dia. storm collar Aluminium cravat type with 100 mm upstand. Used in conjunction with adjustable roof plate.
|
 |
125 dia. malleable roof plate 450 x 450 lead plate with 300 upstand for 15 deg. roof pitch. For use with pantile roof.
|
 |
125 dia. malleable roof plate 450 x 450 lead plate with 300 upstand for 30 deg. roof pitch. For use with pantile roof.
|
 |
125 dia. malleable roof plate 450 x 450 lead plate with 300 upstand for 45 deg. roof pitch. For use with pantile roof.
|
 |
|
 |
125 dia. double inverted cowl
|
 |
125 dia. universal cowl Fitted with bird mesh for use on gas fired appliances only.
|
 |
125 dia. appliance connector Required to connect direct to Midtherm Vitrelux vitreous enamelled flue pipe. Also used to fit into an imperial size boiler spigot.
|
 |
125 dia. locking band One required at each joint.
|
 |
125 dia. structural locking band One required at each joint where extra stability is required.
|
 |
125 dia. rafter support bracket Maintains 50 mm clearance from combustible materials and provides lateral stability.
|
 |
125 dia. stainless steel wall band Used to provide lateral support for a vertical flue. Gives 50 mm clearance from wall.
|
 |
125 dia. adjustable stainless steel wall band Used to provide lateral support for a vertical flue. Gives 50 to 100 mm clearance from wall.
|
 |
125 dia. stainless steel guy wire bracket Provides 3 fixing points for use with guy wires to provide lateral support for exposed vertical flue.
|
 |
125 dia. guy wire kit Comprising of 30m x 3mm wire (SWL = 100kilos per wire), 12 bulldog grips, 3 strainers and 6 thimbes. Used in conjunction with guy wire bracket to provide lateral support for exposed vertical flue. (heavy duty version is available - details / price on request)
|
 |
125 dia. ventilated support plate 346 x 346 ms load bearing ventilated support plate supplied with support collar. For use where the flue system penetrates combustible floors. A load bearing support plate with collar must be positioned every 6 meters.
|
 |
125 dia. non supporting ventilated top plate 346 x 346 ms non supporting ventilated top plate used where the flue system penetrates floors but no load bearing support is required.
|
 |
125 dia. adjustable radiation shield Can be extended to suit the joist height and is set at a diameter to fit in between the flue outer casing and the joist box. Length adjustable to suit joist height from 150 to 250mm when using ventilated firestop c/w fire sealing collar.
|
 |
125 dia. ventilated firestop c/w fire sealing collar 346 x 346 ms ventilated firestop complete with fire sealing collar is designed to meet the requirements of the Building Reguations 2000 Approved Document B. The
|
 |